Sensor Specifications |
||||
|
Part Number |
Gas |
Range |
Resolution |
Accuracy* |
|
054-873 |
Oxygen O2 |
0-30% |
0.1% |
±5% |
|
054-875 |
Carbon Monoxide CO |
0-999 ppm |
1 ppm |
±5% |
|
054-874 |
Hydrogen Sulfide H2S |
0-500 ppm |
1 ppm |
±5% |
|
054-881 |
Chlorine CL2 |
0-20 ppm |
0.1 ppm |
±5% |
|
054-886 |
Hydrogen Cyanide HCN |
0-50 ppm |
0.1 ppm |
±5% |
|
054-879 |
Ammonia NH3 |
0-50 ppm |
1 ppm |
±5% |
|
054-878 |
Sulphur Dioxide SO2 |
0-50 ppm |
0.1 ppm |
±5% |
|
054-877 |
Nitric Oxide NO |
0-100 ppm |
0.1 ppm |
±5% |
|
054-880 |
Nitrogen Dioxide NO2 |
0-50 ppm |
0.1 ppm |
±5% |
|
054-722 |
Ethylene Oxide ETO |
0-20 ppm |
0.1 ppm |
±5% |
|
054-872 |
Combustible Gas (LEL) |
0-100 LEL or |
1% |
±5% |
|
054-876 |
Carbon Monoxide (unfiltered) |
0-999 ppm |
1 ppm |
±5% |
|
054-899 |
Dummy Sensor (required when using 4 or 2 gas with less than 4 or 2 sensors to maintain IP54) |
|||
Sensors for the SafeTest 90 Gas Monitor |
||||
|
054-734 |
Oxygen O2 |
0-30% |
0.1% |
±5% |
|
054-735 |
Carbon Monoxide CO |
0-1500 ppm |
1 ppm |
±5% |
|
054-736 |
Hydrogen Sulfide H2S |
0-500 ppm |
1 ppm |
±5% |
|
054-741 |
Chlorine CL2 |
0-20 ppm |
0.1 ppm |
±5% |
|
054-742 |
Sulphur Dioxide SO2 |
0-50 ppm |
0.1 ppm |
±5% |
|
054-743 |
Nitrogen Dioxide NO2 |
0-50 ppm |
0.1 ppm |
±5% |
Multi-Gas Monitor Accessories |
|
|
Part Number |
Description |
|
054-892 |
Alkaline Battery Pack |
|
054-890 |
NiCad (Nickel Cadmium) Battery Pack |
|
054-891 |
NiMH (Nickel Metal Hydride) Battery Pack |
|
054-898-A |
Single Unit Charger with 120V Transformer |
|
054-898-B |
Single Unit Charger with 220V Transformer |
|
054-898-C |
Single Unit Charger with 12V Automobile Adapter |
|
054-725-A |
Dual Unit Charger with 120-220V Power Supply (includes 120V North American line cord) |
|
054-725-B |
Dual Unit Charger with 120-220V Power Supply (includes 220V Continental European line cord) |
|
054-725-C |
Dual Unit Charger with 12V Automobile Adapter |
|
054-726-A |
Five Unit Charger with 120-220V Power Supply (includes 110V North American line cord) |
|
054-726-B |
Five Unit Charger with 120-220V Power Supply (includes 220V Continental European line cord) |
|
054-727 |
Charger Upgrade Kit: adds additional charger to existing charger. Allows up to a total of five. (Requires 120-220V Power Supply) |
|
054-720 |
QTP-2000 Automatic Sample Draw Pump with 10 ft. of Hose with Butyrate Wand |
|
054-710 |
Probe Assembly for Pump with Butyrate Wand |
|
054-301 |
Replacement Hydrophobic Filter for Probe Assembly - Package of 5 |
|
054-948 |
Hand Aspirator and 10 ft. of Hose |
|
054-105 |
Replacement 3/16 ID Tygon Hose (per foot) |
|
054-703 |
Calibration Adapter |
|
054-714 |
Earphone |
|
054-849-A |
Sensor Hot Box (9V alkaline) |
|
054-849-B |
Sensor Hot Box (110V) |
|
054-849-C |
Sensor Hot Box (220V) |
|
054-715 |
Serial/Computer Interface Cable (RS-232 to PC) for QuestSuite |
|
056-875 |
Parallel Printer Interface Cable |
|
054-848 |
Large Storage Case (Confined Space Entry Kit) |
|
054-965 |
Water Resistant Carrying Case |
|
054-486 |
Protective Leather Case with Shoulder and Chest Strap |
|
054-487 |
Protective Leather Case with Automatic Sample Pump |
Single Gas Monitor Accessories |
|
| Part Number | Description |
|
054-714 |
Earphone |
|
054-948 |
Hand Aspirator with 10 ft. of Hose |
|
054-702 |
Sample Draw (Calibration) Adapter |
|
054-105 |
Replacement 3/16 ID Tygon Hose (per foot) |
|
058-176 |
9 Volt Battery |
|
054-715 |
Serial Printer/Computer Interface Cable (RS-232 to PC) for QuestSuite |
|
056-875 |
Parallel Printer Cable |
|
054-964 |
Storage Case |
|
054-488 |
Protective Leather Carrying Case with Shoulder Strap |
|
054-733 |
Vibratory Alarm for SafeTest 90 |
Two Cylinder Calibration Kit |
|
| Part Number | Description |
|
054-974 |
Includes two cylinder case (gas not included), regulator** (specify from * choices below), and tubing |
Calibration Regulators and Adapters |
|
| Part Number | Description |
|
054-971* |
.5 lpm Regulator w/2 (.050 I.D.) Tubing |
|
054-972* |
1.0 lpm Regulator for Nitrogen Dioxide, Chlorine, Sulphur Dioxide and Hydrogen Chloride w/2 (.050 I.D.) Tubing |
|
054-326 |
On Demand Regulator for use with a Sample Draw Pump |
|
054-973 |
1.0 lpm Corrosive Gas Regulator for Ammonia w/2 (.050 I.D.) Tubing |
|
054-703 |
Calibration Adapter - MultiLog 2000, MultiCheck 2000, SafeCheck 200 |
|
054-702 |
Calibration Adapter - SafeLog 100, SafeCheck 100 |
|
054-737 |
Calibration Adapter - SafeTest 90 |
Calibration Gases - 103 Liter Steel Cylinder |
|
|
Part Number |
Description |
|
054-137 |
2.5% Methane in Air |
|
054-138 |
0.3% Hexane in Air |
|
054-139 |
1.1% Propane in Air |
|
054-140 |
2.0% Hydrogen in Air |
|
054-141 |
100% Nitrogen |
|
054-142 |
50 ppm Carbon Monoxide in Air |
|
054-143 |
200 ppm Carbon Monoxide in Air |
|
054-144 |
50 ppm Carbon Monoxide in Nitrogen |
|
054-145 |
50 ppm Carbon Monoxide/2.5% Methane/17% Oxygen in Nitrogen |
|
054-553 |
200 ppm Carbon Monoxide/2.5% Methane/17% Oxygen in Nitrogen |
Calibration Gases - 58 Liter Aluminum Cylinder |
|
|
Part Number |
Description |
|
054-252 |
25 ppm Hydrogen Sulfide/100 ppm Carbon Monoxide/2.5% Methane/18% Oxygen in Nitrogen |
|
054-554 |
25 ppm Hydrogen Sulfide/200 ppm Carbon Monoxide/2.5% Methane/18% Oxygen in Nitrogen |
|
054-146 |
25 ppm Hydrogen Sulfide in Air |
|
054-423 |
2 ppm Chlorine in Nitrogen |
|
054-147 |
10 ppm Chlorine in Nitrogen |
|
054-148 |
10 ppm Sulphur Dioxide in Air |
|
054-149 |
25 ppm Nitric Oxide in Nitrogen |
|
054-150 |
5 ppm Nitrogen Dioxide in Nitrogen |
|
054-264 |
10 ppm Ammonia in Air |
|
054-265 |
25 ppm Ammonia in Air |
|
054-152 |
10 ppm Hydrogen Cyanide in Nitrogen |
|
054-153 |
10 ppm Hydrogen Chloride in Nitrogen |
|
|
![]() |
|
Copyright © 2005 Coll Health and Safety Inc.
|